Home Partners Area Site Map

About Powercom System & services Solutions System capabilities Contact us
 
 
 
   

Product Name

Three phase-meter integrated GSM module and disconnecting feature

Product Number

PCRG327



 

Technical Specification

                                                     Poly phase meter
Reference voltage                           Vin=3*230/400VAC
Normal voltage                               0.8~1.2Vn
Limited voltage                               0.0~1.25Vn
Reference current                           3*60A
Reference frequency                       50/60Hz
Accuracy                                        Active class 1, Reactive class 2
Power dissipation                           <2.5W
Life time                                        15 years
Failure ratio                                   <0.3%
Clock accuracy                               1sec/day
GPRS                                            class 10                             
Operation temp.                             -25˚C ~+55˚C                         
Display   
                                        LCD with 16 alphanumeric characters

Basic Functions

• Active and reactive energy measurement: active class I and reactive class II according to EN 61036 and EN 61268
• Two communication modes: GSM/GPRS and infrared communication
• Multitariff support: multiple tariff and time period can be configured
• Prepayment support: Credit is downloaded into the meter. Limit value generates notification
• Contractual limit control: built-in Relay Enables the operator to cut off the power
• Configurable LCD display: providing rich and configurable display dataset
• Load restriction adjustment: contractual maximum power and demand can be adjusted
• Load profile recording: 35 days of active and reactive load curve can be saved
• Quality service data recording: detecting and recording of voltage interruption and variation
• Anti-tamper function: detecting of illegal tie-in or unauthorized access to the meter
• Table-like data access: providing flexible data access
• Meter working status diagnosis: giving internal hardware abnormity and reverse phase line connection if any
• Secured communication mode: password authentication method to protect the writing operation in GSM/GPSRS mode and reading & writing operations in local infrared mode
• Meter manufacturing state provided: masking the normal functions that will complicate the manufacturing process

software can be updated via IR comm. or RS232 using a PC or HHU.

push button should be included for data scrolling and power restore in a case of disconnect.

•push button should be included for data scrolling and power restore in a case of disconnect.
 

Copyright 2010 PowerCom LTD. All rights reserved